Erasing Data

To erase the data shown on the screen, tap the ‘Erase’ button at the bottom of the chart. A screen will

ask you to confirm your intentions to erase the data before the data is cleared. NOTE: Erasing the data

with this button will not clear the data from the internal memory of the controller; it will merely remove

it from view in the table. Any erased data is still available for download to USB as described in the next

section.

Downloading Data

To download data to a USB flash drive, insert a flash drive with available memory into the port on the

bottom of the controller. Tap the ‘Export Data’ button at the bottom of the data table, and then select

either to download just the Data Screen Contents, or choose a date range for which you wish to

download the data. Tap the ‘Export’ button to copy the information to the flash drive.

To view the data downloaded to USB, insert the flash drive into a computer and open to view the files

and folders. The controller will create a folder on your flash drive called your controller name (if you

have named your controller ‘Station 1’ in the ‘Controller Information’ screen, you will find a folder on

your flash drive named ‘Station 1’. See the Controller Information section of this manual for more

information). Inside this folder will be a folder called ‘Data’ which contains the files exported to the

flash drive. Note: if multiple days are selected for download, the controller will save a file for each day

on the flash drive. For example, if 5 days are selected for data export, you will find 5 files on the flash

drive (unless the tool was not used during some of those days).