Graph screens – HMC Electronics ASG-SD2500-10FX-SY X-PAQ Precision Fastening System User Manual
Page 29
![background image](/manuals/562127/29/background.png)
Page 29
Graph Screens
In order to assist the user with setting up and trouble-shooting problem joints, the latest rundown is
stored in the controller in graph form. From the ‘Run Tool’ screen, tap the ‘Graph’ button at the bottom
of the screen. Along the bottom of the screen can be found the available graphs, tap the appropriate
button to view:
• Torque vs. Time: Graphs the last rundown with Torque on the Y axis in whatever units are
specified in the parameter, and Time on the X axis in milliseconds (ms).
• Angle vs. Time: Graphs the last rundown with Angle on the Y axis in degrees (deg), and Time on
the X axis in milliseconds (ms).
• Torque vs. Angle: Graphs the last rundown with Torque on the Y axis in whatever units are
specified in the parameter, and Angle on the X axis in degrees (deg).
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
(800) 482-4440
- ASG-SD2500-10PL-SY X-PAQ Precision Fastening System ASG-SD2500-10PS-SY X-PAQ Precision Fastening System ASG-SD2500-20FX-SY X-PAQ Precision Fastening System ASG-SD2500-20PS-SY X-PAQ Precision Fastening System ASG-SD2500-35FX-SY X-PAQ Precision Fastening System ASG-SD2500-35PL-SY X-PAQ Precision Fastening System ASG-SD2500-35PS-SY X-PAQ Precision Fastening System ASG-SD2500-50PL-SY X-PAQ Precision Fastening System ASG-SD2500-50PS-SY X-PAQ Precision Fastening System