Electrical Installation
All electrical connections must be installed by a
qualified electrician.
IMPORTANT
This appliance component requires additional features and components to comply with appliance and
electrical standards. It is the responsibility of the customer and installer to interpret and comply with all
applicable safety and electrical standards. Refer to details in section 4.1 Important Safety and Electrical
Requirements.
Refer to the electrical specifications in chapter 3 Dimensions and Technical Specifications AND the
rating plate/instruction labels on the unit. Always refer to the rating plate/instruction labels on the
unit to verify the electrical data. The rating plate/label information overrides the information listed in this
manual.
Ensure the supply voltage and the line current match the specifications given on the rating plate. A
stable mains supply must be provided.
CAUTION
Wrong voltage will damage the induction unit. Follow
strictly the specifications on the rating plate.
The electrical installation must satisfy the national and local electrical codes.
If ground fault current protective switches are used, they must be provided with selective activation and
designed for a minimum fault current of 30mA. Multiple generators with a mains connection must not be
connected to a single fault current protective switch.
The electrician must equip the generator with a mains cable in accordance with the applicable
regulations. Ensure the mains cable connection is absolutely correct.
All cables must be routed / protected and tension free.
Always route sensor and communication cables separately and away from the coil cables.
To manage electromagnetic interference, excess cable length can be dressed and tied in a
serpentine or S pattern, NOT coiled.
The electrician must ensure the induction unit can always be disconnected from the power supply by a
switch, in accordance with the applicable regulations.
Put the control knob in the 0 (OFF) position BEFORE connecting to the electrical supply.
- MO QU 24000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 21000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 20000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 14000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 14000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 10000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD