6 operating conditions, 7 compliances – Garland MO QU 28000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD User Manual
Page 12

Dimensions and Technical Specifications
RTCSmp Built-In Module-Line Dual/Quad Cooktops
12
Part # 4532415 Rev 3 (8/19/14)
3.6
Operating Conditions
Max. Tolerance of Nominal Supply Voltage
+6 /-10 %
Network Impedance (Zmax.)
0.25Ω
Supply frequency
50/60 Hz
Amperage Nominal Value — 400V, 3Ph
10A for the 7kW generator (4 x 1.5mm
2
)
15A for the 10kW generator (4 x 2.5mm
2
)
2 x 10A for the 14kW generator (2 x (4 x 1.5mm
2
))
Amperage Nominal Value — 208V, 3Ph
20A for the 7kW generator (4x AWG 10)
29A for the 10kW generator (4x AWG 8)
2 x 20A for the 14kW generator (2 x (4 x AWG 10))
Ingress Protection class
IP X0 (Protection by customer required.)
Maximum Ambient Temperature
In Storage -4°F to +158°F (-20°C to +70°C)
In Operation +41°F to +104°F (+5°C to +40°C)
Maximum Relative Air Humidity
In Storage 10% to 90%
In Operation 30% to 90%
Temperature/Power Regulator
Potentiometer 10 kOhm
LED Indicator Lamp
24VDC / max. 40mA (Green)
Clearance from materials for generator
Min. 1.57”(40mm) for air intake and exhaust openings
Min. 0.39”(10mm) for side clearance
Min. Induction Cooking Pan Diameter
5” (12cm)
Max. Air Flow of Fan is 70.63 cfm (120 m
3
/h), Fresh Air Inlet Opening of 10.08 sq. in. (6500 mm
2
) is required.
3.7
Compliances
North American models:
ETL recognized* in compliance with UL 197, CSA C22.2 No.109, NSF-4. Complies with FCC part 18, ICES-001
CE models comply with the latest European Norms:
EN 60335-1, EN 60335-2-36, EN 62233 (EMC/EMV)
*see section 4.1.
- MO QU 24000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 21000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 20000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 14000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 14000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 10000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD