Installation
RTCSmp
Built-In Module-Line Dual/Quad Cooktops
Part # 4532415 Rev 3 (8/19/14)
Page 17
Models: MO DU 14000/ 20000 MO QU 21000/ 24000/ 28000
4.4
Control Unit and Operation Unit (Power Switches)
4.4.1
Location
Distance of the control unit from the coil carrier sheet: MAX 800mm / 31.5”.
Distance of the control unit from the operation units (power switches): MAX 800mm / 31.5”.
Keep the Service Interface window on the control unit accessible for service.
Ensure the equipment and cable connections are accessible for maintenance and service.
4.4.2
Ventilation
It is possible to install the induction unit near heat-producing or steam-producing equipment such as an
oven or a fryer. However, use an external fan to pull hot air, greasy fume, and moisture away from the
induction unit.
The maximum operating temperature for the induction unit must not exceed 104F (40C).
3.98”
(101 mm)
3.98”
(101 mm)
6.22”
(158 mm)
14.17”
(360 mm)
23.62” (600 mm)
23.62” (600 mm)
air
supply
mains connection
field 1
coil connection
field 2
mains connection
field 2
coil connection
field 1
CAN/BUS
6.02” (153 mm)
6.81” (173 mm)
1.57” (40 mm)
0.91” (23 mm)
1.57” (40 mm)
2.09”
(53 mm)
5.16”
(131 mm)
min 1.57” (40 mm)
min 5” (127mm)
air exhaust
clearance
cable bend
clearance
- MO QU 24000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 21000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 20000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO QU 14000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 14000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 10000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 FL INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD MO DU 7000 INDUCTION MODULE-LINE COOKTOPS DUAL/QUAD