Flint & Walling Commander Pro 300 User Manual
Page 16
16
95 North Oak Street • Kendallville, IN 46755
MAGNETIC STARTERS FOR 3 WIRE FRANKLIN MOTORS
Overload Protection • 4”, 6” & 8” Submersible Motors – 60 Cycle – 3 Phase
MOTOR
SIEMENS/FURNAS CLASS 16
STARTER
HEATER
HP
VOLTS
F&W PART NO.
Size Full Load AMPS
F&W PART NO.
SIZE
F&W PART NO.
4” FRANKLIN SUBMERSIBLE MOTORS – 60 HZ – 3 PHASE
1 1/2
200
137457
25
139324
K43
130274
230
137458
K41
130272
460
137460
139325
K29
134872
2
200
137461
25
139324
K50
133010
230
137462
K43
130274
460
137464
139325
K33
130275
3
200
137465
25
139324
K54
130282
230
137466
K52
130276
460
137468
139325
K37
130277
5
200
137469
25
139324
K61
133016
230
137470
K61
133016
460
137472
139325
K49
130280
7 1/2
200
137473
25
139324
K68
130288
230
137474
K67
133020
460
137476
139325
K55
133013
6” & 8” FRANKLIN SUBMERSIBLE MOTORS – 60 HZ – 3 PHASE
5
200
133492
25
139324
K61
133016
230
133493
K61
460
133494
25
139325
K49
130280
7 1/2
200
130646
30
139326
K68
130288
230
126552
25
139324
K67
133020
460
128876
25
139325
K55
133013
10
200
130647
40
139327
K72
131724
230
126554
K70
133018
460
128875
25
139325
K58
130279
15
200
130648
60
139328
K76
130691
230
126555
50
139329
K75
130293
460
128884
25
139325
K64
130281
20
200
130649
75
139330
K78
130289
230
128754
K77
130287
460
128888
40
139331
K69
135548
25
200
130650
120
139332
K86
131725
230
128755
90
139333
K83
133021
460
128890
40
139331
K72
131724
30
230
128964
120
139332
K87
135549
460
128965
50
139334
K74
130285
40
460
021003
75
139335
K77
130287
50
460
021004
90
139336
K83
133021
60
460
023029
91
023032
K87
135549
75*
460
023030
107
023032
K89
023034
100*
460
023031
142
023033
K94
023035
*Denotes 8” motor
CAUTION: WARRANTY ON THREE PHASE SUBMERSIBLE MOTORS IS VOID UNLESS PROPER
QUICK TRIP PROTECTORS ARE USED ON ALL 3 LEAD WIRES.
The characteristics of submersible motors are different from standard motors and special overload protection is required. If the motor is
stalled, the overload protector must trip within approximately 10 seconds to protect the motor windings. In the three phase submersible
motors, the installer must provide the SPECIAL EXTRA QUICK TRIP PORTECTORS AS TABULATED. The heaters given are for ambient
compensated starter boxes; if they are not used, nuisance tripping (over protection) may be experienced at high temperatures and no
protection will exist at low temperatures.
Overload protectors (heaters) for motors of “200-230 volt” ratings should be selected for each installation based on the line voltage
measured at the control panel.