Flint & Walling Commander Pro 75 User Manual
Flint & Walling Equipment
1
95 North Oak Street • Kendallville, IN 46755
Copyright 2012. All Rights Reserved.
COMMANDER PRO 75
COMMANDER PRO 100
COMMANDER PRO 150
Constant Pressure Water Systems
Owners Guide to Installation and Operation
WARNING
IMPORTANT SAFETY INSTRUCTIONS
RULES FOR SAFE INSTALLATION AND OPERATION
1. Read these warnings and instructions carefully.
Failure to follow them could cause serious bodily
injury and/or property damage.
2. Follow all local electrical and safety codes as well
as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
3. The power supply should be a separate circuit,
independent of all other circuits. Be sure it is
equipped with a fuse and disconnect box of ample
capacity.
4. For fire protection, the power supply should be free
of any building, preferably on a direct line from the
transformer. In the event of fire, the wires will not be
destroyed and the water supply not cut-off.
5.
Always disconnect power source before performing
any work on or near the motor or its connected load.
If the power disconnect point is out-of-sight, lock it in
the open position and tag it to prevent unexpected
application of power. Failure to do so could result in
fatal electrical shock.
6.
DO NOT handle pump with wet hands or when
standing in water as fatal electrical shock could occur.
Disconnect main power supply before handling pump
for any reason.
7. Shut off power source when voltage drops 10% below
the rated voltage of the motor.
8. Protect the power cable from coming in contact with
sharp objects, oil, grease, hot surfaces or chemicals.
DO NOT kink the power cable. If damaged replace
immediately.
9.
NEVER leave the control box, fused disconnect
switch, or covers open (either partially or completely)
when not being worked on by a competent electrician
or repairman.
10. Always use caution when operating electrical controls
in damp areas. If possible, avoid all contact with
electrical equipment during thunderstorms or extreme
damp conditions.
11. Install all electrical equipment in protected area to
prevent mechanical damage which could produce
serious electrical shock and/or equipment failure.
12. Pump is designed to pump cold ground water that is
free of air or gases. Decreased pump performance
and life expectancy can occur if the ground water is
not cold (86
°
F/30
°
C) or contains air or gases.
13. Pump and controls must be securely and adequately
grounded as specified in section 250-43 item (A) of
the U.S.A. National Electric Code (NEC) and Section
26-954 Canadian Electrical Code. Failure to do so
could result in a fatal injury.
14.
DO NOT use this pump to pump flammable liquids
such as gasoline, fuel oil, kerosene, etc. Failure to
follow the above warning could result in property
damage and/or personal injury.
The pump is intended for use in a well.
Motor frame must be connected to power supply ground or
fatal electrical shock may result. Do not use this pump in
swimming pools.
15.
Capacitors inside CP WATER
Subdrive controllers can still hold a lethal voltage
even after power has been removed. Allow 10 minutes
for dangerous internal voltage to discharge before
operating the unit.
16.
Use of this unit with motors from
other manufacturers may result in damage to both
motor and electronics.
17.
Do not use power factor correction
capacitor with the CP WATER Subdrive. Damage
will result to both motor and electronics.
NOTE: Pumps with the “CSA” mark are tested to UL
standard UL778 and certified to CSA standard C22.2 No.
108.
023802 A