Flint & Walling Constant Pressure Pumping Stations - ADW2W73 User Manual
Pump station
1
(FW1365)
95 North Oak St. • Kendallville, IN 46755 • 1-800-345-9422
Pump Station
Models ADW2W31, ADW2W51,
ADW2W71, ADW2W73
Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal
injury and/or property damage! Retain instructions for future reference.
FW1365
0411
Supersedes
0610
Key feAtureS Of the ArteSIAn DrIve PuMP StAtIOn
IncluDe:
•
Constant water pressure with a wide range of settings
(30-80 psi) (Note: The maximum obtainable system
pressure is limited by the performance of the pump
installed)
•
Smaller pressure tank can be used
•
No in-rush (power-on transient) current
•
Low motor start-up current (soft-starting)
•
Active Power Factor Correction minimizes input RMS
current
•
Protection features
-
Dry run conditions – using intelligent load monitoring
(see Page 6)
-
High voltage / lightning surge
-
Low line voltage
-
Short circuit
General Safety Information
carefully read and follow all safety instructions in
this manual and on pump. Keep safety labels in good
condition. Replace missing or damaged safety labels.
This is a SAFETY ALERT SYMBOL. When you see
this symbol on the pump or in the manual, look for one of
the following signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that WILL cause serious
personal injury, death or major property damage if ignored.
!
Warns of hazards that CAN cause serious
personal injury or death, if ignored.
Warns of hazards that MAY cause minor
personal injury, product or property damage if ignored.
IMPORTANT: Indicates factors concerned with operation,
installation, assembly or maintenance which could result in
damage to the machine or equipment if ignored.
NOTE: Indicates special instructions which are important but
are not related to hazards.
!
Read these warnings and instructions
carefully. Failure to follow could result in serious bodily injury
and/or property damage.
!
Capacitors inside the Artesian Drive
controller can still hold a lethal voltage even after power
has been removed. Allow 10 minutes for dangerous internal
voltage to discharge before opening the unit.
Do not use power factor correction
capacitors with the Artesian Drive. Damage will result to both
motor and drive.
!
Electrical installations
shall be in accordance with National Electric
Code (NEC) and all applicable local codes
and ordinances. A licensed electrician should
perform installation.
!
Be sure system is connected
to a circuit equipped with a fuse or circuit
breaker of the correct rating.
Always disconnect power
source before performing any work on or near
the controller, motor or its connected load. If
the power disconnect point is out-of-sight, lock
it in the open position and/or tag it to prevent unexpected
application of power. Failure to do so could result in fatal
electrical shock or bodily injury.
DO NOT handle pump with wet
hands or when standing in water as fatal electrical
shock could occur. Disconnect main power supply
before handling system for any reason.
!
Protect the power cable from
coming in contact with sharp objects, oil, grease,
hot surfaces or chemicals. DO NOT kink the
power cable. If damaged replace immediately.
!
NEVER leave the control box,
fused disconnect switch, or covers open (either
partially or completely) when not being worked
on by a competent electrician or repairman.
023423
figure 1
Discharge
Manifold
Pump Intake