Flint & Walling Constant Pressure Pumping Stations - Installation Guide User Manual
Centrifugal constant pressure installation guide, Location, Wire routing 3. grounding

Centrifugal
Constant Pressure
Installation Guide
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all 
safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
FW1101
0711
Supersedes
1008
1. LOCATION
Indoor Use Only
2. WIRE ROUTING
3. GROUNDING
IL0737
4”
Min.
4”
Min.
4”
Min.
4”
Min.
IL0738
IL0739
MOTOR
IL0740
IL0741
IL0742
IL0743
IL0744
Mount the Artesian Drive 
unit as close as possible 
to the service entrance 
panel.
Use a dedicated branch circuit for the Artesian 
Drive. Wire directly from the service entrance 
panel.
Use the holes and 
guides provided
Allow a 4” 
clearance around 
the Artesian 
Drive box for 
cooling
Mount unit to a sturdy 
supporting structure (wall or 
post)
DO NOT drill 
holes in the 
Artesian Drive 
box
DO NOT wire to a sub panel 
located in a home.
It is preferable to wire directly to 
the service entrance panel.
When possible, DO NOT run 
Artesian Drive input power or 
motor wires in parallel with 
house wiring.
Avoid runing out-building wires 
in parallel with motor wires.
Keep input power and motor 
wiring separated by at least 8”.
Input power
Motor
DO NOT run input power and 
motor wires together.
Keep separated by at least 8”
If it is necessary to run wiring in paralell, keep 
Artesian Drive input power and motor wires at least 
8” from other house wiring.
Cross over other branch 
circuits and house wiring 
at 90º
Insure that a 
proper utility 
ground rod is 
present and 
connected.
A dedicated ouput ground 
wire from the Artesian 
Drive must be connected 
to the motor (motor wires 
and ground wires must be 
bundled together).
An input power ground wire from the supply panel 
must be connected to the Artesian Drive.
Use the service 
entrance panel 
ground ONLY
DO NOT run
ground wire separate.
Motor ground wire MUST be 
bundled with motor wires.
Avoid multiple ground paths
Service Entrance 
Panel
Service Entrance 
Panel
Service Entrance 
Panel
Service Entrance 
Panel
Service Entrance 
Panel
Service Entrance 
Panel
Service 
Entrance Panel
IN HOME
Sub Panel
GND
GND
GND
Motor
GND
GND
Motor
Pump
GND
GND
GND
GND
Service
Entrance Panel
Branch 3
Branch 2
Branch 1
8” Min.
8” Min.
Telephone
Motor
8” Min.
Satellite /
Antenna
Wire
GND
GND
8” Min.
OK
8” Min.
90º
GND
GND
GND
8” Min.
GND.
GND.
Motor
Pump
GND.
GND.
Motor
Pump
GND.
GND.
GND.
GND.
GND.
Motor
Pump
022688
Insure that a proper utility ground 
rod is present and connected.
IL0783
Motor
Power to 
Motor
Power Supply from Circuit 
Breaker
Inlet
Outlet
Inlet
Outlet
Inlet
Outlet
Inlet
Outlet
Inlet
Outlet