Flint & Walling Artesian Drive Controllers - AD150145 User Manual
Page 6
6
(FW1086)
95 North Oak St. • Kendallville, IN 46755 • 1-800-345-9422
GND
GND
Output
to
Motor
L1
L2
L3
U
V
W
PE
PE
IL0731
Figure 6
5. Feed the motor supply cable and 230 VAC power leads
through the bottom right and left strain reliefs respectively.
Connect the motor ground and power supply ground wires
the terminal block marked GND and PE respectively.
!
Because of the leakage current produced
by the internal filtering, permanent fixed ground connections
must be made using two independent conductors each with a
cross-section equal to or exceeding that of the supply conduc-
tors. The drive is provided with two ground terminals marked
PE to facilitate this.
6. Connect motor supply leads to terminal block positions
marked U, V and W (right hand side). Connect power leads
to terminals marked L1 and L3 (left hand side).
Note: For correct motor rotation and pump performance on
F&W manufactured motors, leads 1-7, 2-8 & 3-9 on the motor
should be connected to U, V & W respectively. Three phase
motors from other manufactures may require that connection
U & V be switched at the drive for proper motor rotation and
performance.
GND
1
2
IL0732
B2
B5
B4
L1 L2 L3 U V W
PE
PE
Figure 7
7. Feed the pressure sensor leads through the smaller strain
relief on the bottom of the Artesian Drive unit and connect
the red and black leads to the terminals marked “B2” and
“B5” (interchangeable) with a small screwdriver (provided).
Make sure to not disconnect the factory installed jumper
wire that is already connected to terminal “B2”.
NOTE: A 10-foot section of pressure sensor cable is provided
with the controller, but it is possible to use similar 20 AWG
wire for distances up to 100 feet from the pressure sensor.
8. Slide the lower enclosure cover into position and tighten
screw on bottom lip as show.
IL0747
Figure 8
9. Press the memory stick guard into the slot in the front cover
as shown; do not press fully into position. Replace the front
cover. Do not over-tighten the screw.
IL0779
Figure 9
IL0730
Remove
Rubber End
Cap to Adjust
Pressure with
7/32” Allen
Wrench
Pressure Sensor
Boot
Figure10 - Pressure sensor
10. Connect the other end of the pressure sensor cable with the
two spade terminals to the pressure sensor. The connections
are interchangeable.
11. Set the pressure tank pre-charge at 70% of the desired
water pressure setting. To check the tank’s pre-charge, de-
pressurize the water system by opening a tap. Measure the
tank pre-charge with a pressure gauge at its inflation valve
and make the necessary adjustments.
12. The pressure sensor communicates the system pressure to
the Artesian Drive controller. The sensor is preset at the
factory to 50 psi, but can be adjusted by the installer using
- Artesian Drive Controllers - AD096096 Artesian Drive Controllers - AD096074 Artesian Drive Controllers - AD070059 Artesian Drive Controllers - AD052045 Centrifugal Packages - AD150145 Centrifugal Packages - AD096096 Centrifugal Packages - AD096074 Centrifugal Packages - AD070059 Centrifugal Packages - AD052045