beautypg.com

Flint & Walling Artesian Drive Controllers - AD150145 User Manual

Page 2

background image

2

(FW1086)

95 North Oak St. • Kendallville, IN 46755 • 1-800-345-9422

!

Read these warnings and instructions

carefully. Failure to follow could result in serious bodily injury
and/or property damage.

!

Capacitors inside the Artesian Drive

controller can still hold a lethal voltage even after power
has been removed. Allow 10 minutes for dangerous internal
voltage to discharge before opening the unit.

Do not use power factor correction

capacitors with the Artesian Drive. Damage will result to both
motor and drive.

!

Electrical installations

shall be in accordance with National Electric
Code (NEC) and all applicable local codes
and ordinances. A licensed electrician should

perform installation.

!

Be sure system is connected

to a circuit equipped with a fuse or circuit
breaker of the correct rating.

Always disconnect power

source before performing any work on or near
the controller, motor or its connected load. If
the power disconnect point is out-of-sight, lock

it in the open position and/or tag it to prevent unexpected
application of power. Failure to do so could result in fatal
electrical shock or bodily injury.

DO NOT handle pump with wet

hands or when standing in water as fatal electrical
shock could occur. Disconnect main power supply
before handling system for any reason.

!

Protect the power cable from

coming in contact with sharp objects, oil, grease,
hot surfaces or chemicals. DO NOT kink the
power cable. If damaged replace immediately.

!

NEVER leave the control box,

fused disconnect switch, or covers open (either
partially or completely) when not being worked
on by a competent electrician or repairman.

Always use caution when

operating electrical controls in damp areas. If possible,
avoid all contact with electrical equipment during
thunderstorms or extreme damp conditions.

!

Install all electrical equipment

in protected area to prevent mechanical damage
which could produce serious electrical shock and/
or equipment failure.

DO NOT use this system to pump

flammable liquids such as gasoline, fuel oil, kerosene,
etc. Failure to follow the above warning could result
in property damage and/or personal injury.

!

This product contains chemicals known
to the State of California to cause

cancer and birth defects or other reproductive harm.

Do not pump water above 140 degrees
Fahrenheit.

!

This unit not tested for use

in swimming pool areas.

how it Works

The F&W Artesian Drive is designed to be part of a system
that consists of only four major components:
A. Standard Pump and Three Phase Motor.
B. Artesian Drive Controller.
C. Small Pressure Tank (for tank size, see Table 2).
D. Pressure Sensor (provided).

Pressure

Sensor

Leads

Tank

Outlet

Pump

Motor

Inlet

Pressure

Relief Valve

Power to

Motor

Power Supply from

Circuit Breaker

Constant Pressure

Diagram

IL0729

Figure 2a - Constant Pressure Diagram for booster pumps

IL0783

Pressure

Sensor

Leads

Tank

Outlet

Pump

Motor

Inlet

Pressure

Relief Valve

Power

to

Motor

Power Supply from

Circuit Breaker
Figure 2b - Constant Pressure Diagram for centrifugal pumps

Constant Pressure

The F&W Artesian Drive provides consistent pressure regula-
tion using custom programming to run a standard motor
and pump according to the pressure demands indicated by
a heavy duty pressure switch. By adjusting the motor/pump
speed, the Artesian Drive can deliver consistent pressure