beautypg.com

Flint & Walling Artesian Drive Controllers - AD150145 User Manual

Page 11

background image

11

(FW1086)

95 North Oak St. • Kendallville, IN 46755 • 1-800-345-9422

IL0733

B2

B5

B4

B2

B5

B4

L1

L2

L3

U

V

W

PE

PE

L1

L2

L3

U

V

W

PE

PE

L1

L2

L3

U

V

W

PE

PE

GND

Pressure Sensor Cable (Included)

Motor

Inlet

Pump

Pressure

Gauge

Outlet

Pressure Relief

Valve

Drain Valve

Pressure

Sensor

To

Service

Discharge into drain rated for max pump output at

relief pressure

Pressure

Tank

tABle 2: MInIMuM Pressure tAnK

Rated Pump Flow

Pressure Tank Size (Total

Volume)

Pump Capacity less than 12

GPM

4 Gallon (AT15)

Pump Capacity greater than

12 but less than 25 GPM

8 Gallon (AT25)

Pump Capacity greater than

25 GPM

14 Gallon (AT44)

The pressure tank pre-charge setting should be 70% of the system pressure
sensor setting as indicated in the following table.

tABle 3: Pressure tAnK AIr PreChArGe
(PsI)

System Pressure (at

Pressure Sensor)

Pressure Tank

Precharge Setting (± 2

PSI)

30

21

35

25

40

28

45

32

50

35

55

39

60

42

65

46

70

49

75

53

80

56

*NOTE: High pressure applications above 80
PSI should be addressed through the Tech
Support group at Flint & Walling (1-800-345-
9422).

Isolation

Valves

Check Valve

Check Valve

From Municipal

Tank Precharge

Inflation Valve