Technical data, Combination options – EUCHNER CMS-E-BR User Manual
Page 7
Figure 1: Dimension drawing evaluation unit CMS-E-BR
Suitable for 35-mm mounting rail acc. to DIN EN 60715 TH 35
31
41
1A
2A
1
2
3
4
5
6
7
8
81
71
61
51
21
11
01
9
42
32
2Y
1Y
11
D
22
D
21
D
12
D
13
D
23
D
14
D
24
D
BU
TU
O
75
50
1
7,
41
1
45
Technical data
Parameter
Value
Unit
Housing material
PC
Dimensions
114.7 x 75 x 45
mm
Weight
0.24
kg
Ambient temperature
0 ... +50
°C
Storage temperature
-25 ... +70
°C
Degree of protection acc. to EN 60529
Terminals IP20 / housing IP40
Degree of contamination
2
Mounting
Mounting rail 35 mm acc. to DIN EN 60715 TH35
Number of read heads
1 ... 4
Connection
Plug-in connection terminals
Operating voltage U
B
24 ±10%
V AC/DC
Internal fuse (operating voltage U
B
)
500 (automatically resetting fuse PTC)
mA
Safety contact
1
Auxiliary contact
1
Switching voltage U
max.
250
V AC
Typ. current consumption
250
mA
Switching current I
max.
at 24 V
3
A
Switching current, I
min.
at 24 V
13
mA
Breaking capacity P
max.
750
VA
External contact fuse (safety circuit)
acc. to EN IEC 60269-1
3
A gG
Utilization category
I
e
1)
U
e
1)
According to EN 60947-5-1 AC-1
3 A
250 V
AC-1
3 A
24 V
AC-15
1 A
250 V
AC-15
1 A
24 V
DC-13
3 A
24 V
Switching load acc. to UL Class 2
Input:
24 V
AC/DC
Output:
30 V
AC
24 V
DC
Rated insulation voltage U
i
250
V AC
Vibration resistance
According to EN 60947-5-2
Mechanical operating cycles, relay
30 x 10
6
EMC compliance
According to EN 60947-5-3
Risk time according to EN 60947-5-3
20
ms
Reliability values according to EN ISO 13849-1
as a function of the switching current
at 24 V DC
≤
0.1
≤
1
≤
3
A
Number of switching cycles/year
< 100,000
< 18,500
< 9,000
Mission time
20
years
Category
1 read head
4
>1 read head
3
Performance Level (PL)
1 read head
e
>1 read head
d
PFH
d
1 read head
2.5 x 10
--8
>1 read head
1.0 x 10
-7
1) I
e
= max. switching current per contact, U
e
= switching voltage
Combination options
Design
Read head
Circuit
diagram not
actuated
2)
Actuator
Assured
switch-on
distance s
ao
[mm]
2)
Assured
switch-off
distance s
ar
[mm]
Evaluation unit CMS-E-BR,
CMS-R-AXH/-SC
3)
BN
WH
BK (YE)
BU (GN)
CMS-M-AC
6
31
CMS-R-BXI/-SC
CMS-M-BD
3
12
M25
CMS-R-CXC/-SC
CMS-M-CA
6
14
M30
CMS-R-EXM/-SC
CMS-M-EF
6
17
2) Old conductor coloring in brackets.
3) The minimum switching distance S
omin
between read head and actuator is 1 mm. If the distance is
less than this, the evaluation unit changes to the fault state.