Backplane settings – ETC Sensor CE Rack (ESR) ECEM to CEM3 Retrofit User Manual

Page 11

background image

2

The Retrofit

9

Backplane Settings

Upgrade kit backplanes ship from the factory with all DIP switches in the off (down) position.

You will have to set the DIP switches on the new backplane to match your rack. You will

also have to verify the termination switch settings.

a: Set both termination switches to “Off” (middle position) for all racks except the

last rack in your system.

b: Set the termination switches for the last rack in the system to “ON” (top

position).

c: Using a precision screwdriver, set the DIP switches to match your rack type

according to:

• number of modules (12, 24, 36 or 48)

• whether the rack has Advanced Features (AF)

Use the following chart to determine your required DIP switch settings:

“On” position = switch pushed to the top

d: Check to see that the “Emergency Contact” switch is set to the appropriate

position.

• If your system has no panic circuit, the switch should be set to the middle

position, “DISABLED”.

• If your panic circuit includes a Normally Open contact closure, the switch

should be set to the top position (NO).

• If your panic circuit includes a Normally Closed contact closure, the switch

should be set to the bottom position (NC).

DIP switch Number

Rack Model

1

2

3

4

5

6

7

8

ESR3-12

On

On

ESR3-12N

On On

On

ESR3-12AF

On

On

On

ESR3-12AFN

On

On On

On

ESR3-24

On

On

ESR3-24N

On On

On

ESR3-24AF

On

On

On

ESR3-24AFN

On

On On

On

ESR3-36

On

On

ESR3-36N

On On On

ESR3-36AF

On

On

On

ESR3-36AFN

On

On On On

ESR3-48

On

ESR3-48N

On On

ESR3-48AF

On

On

ESR3-48 AFN

On

On On

Set termination to “Off”

(middle position)

Set DIP switches

Emergency Contact

(Panic) switch