beautypg.com

Troubleshooting, Led indicators – ETC Source Four Revolution User Manual

Page 42

background image

38

Source Four Revolution User Manual

Troubleshooting

LED Indicators

The easiest way to find out the status of your Source Four Revolution fixture is to look at

the LED indicators on the upper enclosure. These LEDs are located on the top of the upper

enclosure when the fixture is sitting on its base. When the fixture is hung on a pipe, the

LEDs are visible to technicians standing below the fixture.

Green

Amber

Red

Off

No Power

Lamp OK

Calibration

Successful

On

Receiving DMX

Signal

a

b

a) Green and amber blinking together indicates that there is potential software corruption.

Recycle power. If this indication persists, contact ETC customer service.

b) Red and green blinking together indicates that the thumbwheel address is set higher

than 481. Reset thumbwheel to 481 or lower. See

Connections and Addressing, page

8

for further information.

Lamp Out

Calibration in

Progress

- or -

Error

Blinking

(1/second)

Not Receiving

DMX Signal

Fast Blinking

(5/second)

Self-Test Mode

1

2


3 4

5

6

7

8

9

1

2


3 4

5

6

7

8

9

1

2


3 4

5

6

7

8

I

O

LED Location

Green

Red

Amber