Specifications table – Enerpac WSC-112 User Manual
Page 3
3
3
SPECIFICATIONS TABLE
Maximum Holding Force
vs.
Hydraulic Operating Pressure
WFC / WSC 72
Support Plunger Deflection
vs.
Applied Load
at 350 bar (5000 psi)
Operating Pressure
WFC / WSC 72
0
7,78 (1750)
6,67 (1500)
5,56 (1250)
4,45 (1000)
3,34 (750)
2,22 (500)
1,11 (250)
70
(1000)
140
(2000)
210
(3000)
280
(4000)
350
(5000)
Maximum Holding For
ce
kN (lbs.)
Operating Pressure
bar (psi)
0
.0015 (0,038)
.0010 (0,025)
.0005 (0,013)
(1,78)
400
(3,56)
800
.0030 (0,076)
.0025 (0,064)
.0020 (0,051)
(7,12)
1600
(5,34)
1200
(8,90)
2000
Elastic Deflection
mm (inches)
Applied Load
kN (lbs.)
0
500
(2,22)
1000
(4,45)
1500
(6,67)
2000
(8,90)
(11,12)
2500
.0005 (0,013)
.0020 (0,051)
.0015 (0,038)
.0010 (0,025)
.0025 (0,064)
.0030 (0,076)
Maximum Holding Force
vs.
Hydraulic Operating Pressure
WFC / WSC 112
Maximum Holding For
ce
kN (lbs.)
Support Plunger Deflection
vs.
Applied Load
at 350 bar (5000 psi)
Operating Pressure
WFC / WSC 112
Elastic Deflection
mm (inches)
.0025 (0,064)
.0005 (0,013)
0
.0020 (0,051)
.0010 (0,025)
.0015 (0,038)
1,000
(4,5)
2,000
(8,9)
.0030 (0,076)
3,000
(13,4)
4,000
(17,8)
5,000
(22,3)
0
4,45 (1000)
8,90 (2000)
13,4 (3000)
17,8 (4000)
22,3 (5000)
70
(1000)
140
(2000)
210
(3000)
280
(4000)
350
(5000)
Maximum Holding Force
vs.
Hydraulic Operating Pressure
WFC 222 / WSC 222
Maximum Holding For
ce
(kN) lbs.
Support Plunger Deflection
vs.
Applied Load
at 5000 psi (350 bar)
Operating Pressure
WFC 222 / WSC 222
Elastic Deflection
mm (inches)
Applied Load
kN (lbs.)
Operating Pressure
bar (psi)
Applied Load
kN (lbs.)
Operating Pressure
bar (psi)
0
2,22 (500)
4,45 (1000)
6,67 (1500)
8,90 (2000)
11,12 (2500)
70
(1000)
140
(2000)
210
(3000)
280
(4000)
350
(5000)