Enerpac W-Series User Manual
Page 15
ENGLISH
15
6.2.2 Imperial system table
Drive unit
Fastener
Hexagon size
(H)
(G)
Weight
head
inch
inch
inch
lbs
W2000
W2107
1
7
/
16
1.22
2.11
4.2
W2108
1
1
/
2
1.32
2.29
4.4
W2110
1
5
/
8
1.32
2.29
4.4
W2113
1
13
/
16
1.44
3.38
4.4
W2200
2
1.54
2.48
4.4
W2203
2
3
/
16
1.65
2.70
4.6
W2206
2
3
/
8
1.75
2.55
4.8
W4000
W4203
2
3
/
16
1.73
2.89
8.4
W4206
2
3
/
8
1.83
2.78
8.6
W4208
2
1
/
2
1.95
3.00
8.6
W4209
2
9
/
16
1.93
3.00
8.6
W4212
2
3
/
4
2.07
3.08
8.8
W4215
2
15
/
16
2.19
3.21
9.0
W4302
3
1
/
8
2.30
3.29
9.3
W8000
W8209
2
9
/
16
2.20
3.34
17.2
W8212
2
3
/
4
2.20
3.34
17.2
W8215
2
15
/
16
2.28
3.35
17.2
W8302
3
1
/
8
2.38
3.52
17.4
W8308
3
1
/
2
2.60
3.63
17.9
W8312
3
3
/
4
2.91
4.05
19.4
W8314
3
7
/
8
2.91
4.05
19.2
W15000
W15302
3
1
/
8
2.54
3.66
30.2
W15308
3
1
/
2
2.74
3.80
28.7
W15312
3
3
/
4
2.95
4.01
31.8
W15314
3
7
/
8
2.95
4.01
31.8
W15402
4
1
/
8
3.17
4.06
32.4
W15404
4
1
/
4
3.17
4.06
32.4
W15410I
4
5
/
8
3.44
4.52
33.7
6.3
Torque settings
To set the torque, adjust the pump pressure according to the following calculation:
–
Pump pressure = Torque / Torque factor
Torque factor
W2000
W4000
W8000
W15000
Metric system
3,932
7,863
15,728
29,488
Imperial system
0.2
0.4
0.8
1.5