Enerpac W-Series User Manual
Page 12
12
ENGLISH
•
As a check, the table below indicates
the correct height for the drive unit
retaining pin (X) and the fail safe pin
(Y).
X X Y
Y
(mm)
(inch)
(mm)
(inch)
W2000
4,00
.157
3,00
.118
W4000
5,00
.197
3,00
.118
W8000
6,00
.236
4,00
.157
W15000
7,00
.275
6,00
.236
•
Reverse the procedure to reassemble
the tool.
5.3
Trouble shooting
5.3.1 Drive Unit
Symptom
Cause
Remedy
Cylinder does not advance or retract
Quick-connect coupling
Replace the coupling
is damaged
Quick connect- coupling is
Reconnect the hoses
not connected
and couplings securely
Dirt in the direction control valve Disassemble the unit and
on the pumping unit
clean the valve
Cylinder does not build up pressure
Piston seal leaks
Replace the seals
Pump does not build up pressure Adjust the pressure
Pump is defective
Refer to the pump manual
Cylinder leaks
Seal failure
Replace the cylinder seals
Cylinder operates backwards
Connections are reversed
Reconnect the hoses
5.3.2 Fastener head
Symptom
Cause
Remedy
Ratchet returns on retract stroke
Broken drive shoe
Replace the drive shoe
Ratchet does not take
Defective drive shoe
Replace the drive shoe
successive strokes
Lubricant on the ratchet
Disassemble the head and
and/or drive shoe splines
remove the lubricant
from splines
X
Y
Fig. J