Chapter 3: installation, Before you begin, Site requirements – ElmoMC SimplIQ Analog Servo Amplifiers-Cymbal User Manual
Page 11: Unpacking the amplifier, Chapter 3, Installation

Cymbal Installation Guide
MAN-CYMIG (Ver. 1.3)
11
Chapter 3:
Installation
3.1. Before You Begin
3.1.1.
Site Requirements
You can guarantee the safe operation of the Cymbal by ensuring that they are installed in an
appropriate environment.
Feature
Value
Ambient operating temperature
0 °C to 50 °C (32 °F to 122 °F)
Maximum non‐condensing humidity
90%
Operating area atmosphere
No flammable gases or vapors permitted in area
Note:
Models for extended environmental conditions are available.
Caution: The Cymbal dissipates its heat by convection. The maximum ambient
operating temperature of 0 °C to 50 °C (32 °F to 122 °F) must not be exceeded.
3.2. Unpacking the Amplifier
To unpack the Cymbal:
1. Carefully remove the servo amplifier from the box and the Styrofoam.
2. Check the amplifier to ensure that there is no visible damage to the instrument. If any
damage has occurred, report immediately to the carrier that delivered your amplifier.
3. To ensure that the Cymbal you have unpacked is the appropriate type for your
requirements, find the part number sticker on the side of the product:
The P/N gives the type designation as follows:
4. Verify that the Cymbal type is the one that you ordered, and ensure that the voltage meets
your specific requirements.
www.elmomc.com