I/os, Digital input interfaces – ElmoMC SimplIQ Digital Servo Drives-Bell Installation Guide User Manual
Page 53
Bell Installation Guide
Bell Technical Specifications
MAN-BELIG (Ver. 1.302)
53
4.6. I/Os
The Bell has:
•
6 Digital Inputs
•
2 Digital Outputs
•
1 Analog Input
4.6.1.
Digital Input Interfaces
Feature
Details
Connector
Location
Type of input
•
Optically isolated
•
All six inputs share one signal return line
1.4
3K
Digital Input
Schematic
Input current
for all inputs
Iin = 2.4 mA @ 5 V
High-level input
voltage
2.5 V < Vin < 10 V, 5 V typical
Low-level input
voltage
0 V < Vin < 1 V
Minimum pulse
width
> 360 μsec
Execution time
(all inputs):
the time from
application of
voltage on input
until execution
is complete
If input is set to one of the built-in functions —
Home, Inhibit, Hard Stop, Soft Stop, Hard and Soft
Stop, Forward Limit, Reverse Limit or Begin —
execution is immediate upon detection:
0
on the program. Typical execution time: ≅ 0.5
msec.
High-speed
inputs – 5 & 6
minimum pulse
width, in high-
speed mode
T < 5 µsec
Notes:
•
Home mode is high-speed mode and can be
used for fast capture and precise homing.
•
High speed input has a digital filter set to the
same value as the digital filter (EF) of the main
encoder.
•
Highest speed is achieved when turning on the
optocouplers.