beautypg.com

I/os, Digital input interfaces – ElmoMC SimplIQ Digital Servo Drives-Bell Installation Guide User Manual

Page 53

background image

Bell Installation Guide

Bell Technical Specifications

MAN-BELIG (Ver. 1.302)

|

www.elmomc.com

53

Table of Contents

4.6. I/Os

The Bell has:

6 Digital Inputs

2 Digital Outputs

1 Analog Input

4.6.1.

Digital Input Interfaces

Feature

Details

Connector

Location

Type of input

Optically isolated

All six inputs share one signal return line

1.4

3K

Digital Input

Schematic

Input current
for all inputs

Iin = 2.4 mA @ 5 V

High-level input
voltage

2.5 V < Vin < 10 V, 5 V typical

Low-level input
voltage

0 V < Vin < 1 V

Minimum pulse
width

> 360 μsec

Execution time
(all inputs):
the time from
application of
voltage on input
until execution
is complete

If input is set to one of the built-in functions —
Home, Inhibit, Hard Stop, Soft Stop, Hard and Soft
Stop, Forward Limit, Reverse Limit or Begin —
execution is immediate upon detection:
0If input is set to General input, execution depends
on the program. Typical execution time: ≅ 0.5
msec.

High-speed
inputs – 5 & 6
minimum pulse
width, in high-
speed mode

T < 5 µsec

Notes:

Home mode is high-speed mode and can be

used for fast capture and precise homing.

High speed input has a digital filter set to the

same value as the digital filter (EF) of the main
encoder.

Highest speed is achieved when turning on the

optocouplers.