Elkhart Brass Sidewinder 7161 EXM UHP User Manual
Page 18

EXM UHP– Operating Instructions
18
E. Keep-Out Zones
Keep-Out Zones are used when it is desired to restrict the motion of the monitor to a smaller more specific
range than that set during system calibration. Keep-Out Zones are different from travel limits in that they do
not restrict motion completely in any one direction. Keep-Out Zones can be set to allow the monitor to move
above a certain zone or beside the zone to either the left or right.
Lower-Right Keep-Out Zone - The Right Keep-Out Zone will prevent the monitor from moving down
and to the right into a specified zone (reference figure 1 on the following page)
o Put the EXM system into Setup Mode (reference Part B of the Operating Instructions section)
o Move the monitor to the upper left corner of the keep out zone
o The Keep-Out Zone should be set within the previously set monitor calibration points. If a Keep-
Out Zone is set outside the intended operating area, operation of the monitor may be unpredictable.
o Press the PRESET and OPEN buttons at the same time
o When the EXM system is taken out of Setup Mode, the monitor will be prevented from moving
below and to the right of this point
Lower-Left Keep-Out Zone - The Left Keep-Out Zone will prevent the monitor from moving down and
to the left into a specified zone (reference figure 1 below)
o Put the EXM system into Setup Mode (reference Part B of the Operating Instructions section)
o Move the monitor to the top right corner of the keep out zone
o The Keep-Out Zone should be set within the previously set monitor calibration points. If a Keep-
Out Zone is set outside the intended operating area, operation of the monitor may be unpredictable.
o Press the PRESET and CLOSE buttons at the same time
o When the EXM system is taken out of Setup Mode, the monitor will be prevented from moving
below and to the left of this point
Figure 1 – Keep-Out Zones