General information on programming the preset time
The mobile unit of the radio remote
control can be used to program 3 preset
times.
The 3 preset times can either all be
spread over one weekday or be spread
between different weekdays.
In water heaters and a temperature sen-
sor connected to the stationary unit the
heater start is automatically calculated
depending on the measured ambient
temperature and the selected heating
level (ECO or HIGH).
The operating time can be between 5 and
60 minutes before the programmed de-
parture time, whereby operation is always
stopped 5 minutes after the programmed
departure time. Therefore the minimum
possible operating time is 10 minutes and
the max possible operating time is 65
minutes.
The operating time set in the “set time”
menu (page 8) is ineffective in this case.
In all other configurations the start takes
place according to the preset operating
time.
• The preset times are always departure
times, even if runtime calculation is
deactivated.
• You cannot program more than 3 preset
times.
• The maximum operating time of 65 min-
utes for automatic runtime calculation is
a factory setting. If necessary, this can
be reduced by the installation workshop
to a minimum of 15 minutes.
Identical preset times
If several identical preset times are
programmed for a specific weekday in
programs 1, 2 or 3 the last entered preset
time is valid. When the mobile unit of
the radio remote control is activated the
saved identical preset times are deleted.
If identical preset times are programmed
for different weekdays there is not conflict.
Overlapping of preset times
Example:
You have set “heat” mode for your
departure time on a weekday to 13 hrs.
At the same time “ventilate” mode has
been programmed for 12.45 hrs on the
same day and with an operating time of
15 minutes. What happens?
The radio remote control calculates
the heater start for “heat” mode which,
depending on the ambient temperature
measured, can lie between 5 and 60
minutes before the programmed depar-
ture time. If the calculated heater start is
after 12.45 hrs, the vehicle is ventilated
between 12.30 hrs and 12.45 hrs and is
then heated.
If the calculated heater start is before
12.45 hrs, the vehicle is heated until
12.30 hrs, then the heater is stopped and
the heater switches to “ventilate” mode.
After the set operating time for “ventilate”
mode has expired the heater switches off.