Control Company 3652 ANEMOMETER/HYGROMETER/THERMOMETER/DEW POINT BAROMETER PEN User Manual

Page 2

background image

2. Press and hold the HOLD button for
approximately five (5) seconds, the unit of

measure will flash on the display.

3. Release the HOLD button and press the

POWER button, each press of the POWER
button will cycle the display through the

available units of measure (m/S→Km/h→
FPM→mph→Knot→m/S...).

4. Once the desired unit of measure appears,
press the HOLD button.

The unit of measure selected will be the default unit of measure until
changed.

SELECTING BAROMETER UNIT OF MEASURE
1. Place the meter into one of the following display

modes that displays a barometer reading:
Bar/An, Bar/Rh, or Bar/Tmp (see the “Display
Modes” section).


2. Press and hold the HOLD button for
approximately five (5) seconds, the unit of

measure will flash on the display.

3. Release the HOLD button and press the

POWER button, each press of the POWER
button will cycle the display through the

available units of measure (hPa→mmhg→
inHg→hPa...).

4. Once the desired unit of measure appears,
press the HOLD button.

The unit of measure selected will be the default unit of measure until
changed.

HOLD FUNCTION
The hold function allows the readings on the

display to be “frozen” so that they may be recorded.

1. Press and release the HOLD button to “freeze”

the display at the current reading. “HOLD” will
appear at the top of the display.

2. Once the reading has been recorded, press and
release the HOLD button to return the display to
the current reading. “HOLD” will no longer

appear on the display.

RECORD MODE

(Min/Max Memories)

While in the Record Mode, the maximum and
minimum readings for Humidity (rH/Tmp or rH/dP mode), Barometric

Pressure (Bar/An, Bar/Rh, or Bar/Tmp mode) or Air Flow (An/Tmp mode) will
be recorded, depending on the display mode (see the “Display Modes”
section).

Record Mode records the minimum/maximum values achieved for the upper
display only. While in the Record Mode, the Automatic Shutoff feature is

disabled so that long term monitoring may be performed.

1. Select the desired display mode (see the

“Display Modes” section).

2. To enter the Record Mode, press and release
the REC button. “REC” will appear on display.

3. To recall the maximum and minimum readings
achieved since entering the Record Mode
(“REC” appearing on the display), press and

release the REC button.

4. The first press of the REC button will display

the maximum reading achieved since entering
the Record Mode. (“REC MAX” will appear on

the display).

5. The second press of the REC button displays

the minimum reading achieved since entering
the Record Mode. (“REC MIN” will appear on
the display).


6. To return the display to the current reading,
press and release the HOLD button. “MAX” or

“MIN” will no longer appear on the display.

7. To exit from the Record Mode, press and hold
the REC button for 3 seconds. “REC” will no
longer appear on the display. The maximum

and minimum readings are automatically
cleared once the Record Mode has been exited.

AUTOMATIC SHUTOFF (Disable)
If no button has been pressed for ten (10) minutes, the Automatic Shutoff
feature will turn the meter off to preserve battery life.


The automatic shutoff feature setting is overridden while in the Record Mode.
(See the “Record Mode” section)


To disable the Automatic Shutoff feature, place the unit into the Record

Mode (see the “Record Mode” section).

ALL OPERATION DIFFICULTIES

If this meter does not function properly for any reason, replace the batteries
with a new, high quality batteries (see the “Battery Replacement” section).
Low battery power can occasionally cause an number of “apparent”

operational difficulties. Replacing the batteries with new fresh batteries will
solve most difficulties.