beautypg.com

33 minimum/maximum horizontal sync locking, read, 34 sync locking, read, 35 sync locking, write – Barco RS232 User Manual

Page 160: 32 i 2 c diagnosis, read, 158 3.31.34 sync locking, read, 158 3.31.35 sync locking, write, 32 i, C diagnosis, read, Minimum/maximum horizontal sync locking, read, Sync locking, read

background image

3. Advanced Commands

3.31.33 Minimum/Maximum Horizontal Sync locking, Read

Description

Reads the minimum/max Sync locking

Commands

read minimum:

Command [0]

\x26

Command [1]

\xab

read maximum:

Command[0]

\x27

Command[1]

\xab

Returned Data

Data [0] = byte : 0 = slow ; 1 = fast

3.31.34 Sync locking, Read

Description

Reads the Sync locking setting

Command

Command [0]

\x21

Command [1]

\xab

Returned Data

Data [0] = byte : 0 = slow ; 1 = fast

3.31.35 Sync locking, Write

Description

Sets the Sync locking (fast or slow)

Command

Command [0]

\x20

Command [1]

\xab

Data

Data [0] = byte : 0 = slow ; 1 = fast

3.32 I

2

C diagnosis, Read

Description

Reads the I

2

C diagnosis.

Command

Command [0]

\x81

Command [1]

\x01

158

R5976884 RLM SERIES 04/04/2006