24 gain control, increment/decrement, 25 minimum/maximum agc value, read, 138 3.25 minimum/maximum agc value, read – Barco RS232 User Manual
Page 140: Gain control, increment/decrement, Minimum/maximum agc value, read

3. Advanced Commands
Receive (acknowledge)
Checksum
\x07
Stop
\xff
Receive (awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa2
Data[0]
\x0a
Data[1]
\x00
Checksum
\xce
Stop
\xff
3.24 Gain Control, Increment/Decrement
Description
Increments/decrements the Gain Control value by one
Commands
increment:
Command [0]
\x22
Command [1]
\xa2
decrement:
command[0]
\x23
command[1]
\xa2
3.25 Minimum/Maximum AGC value, Read
Description
Reads the minimum/maximum AGC(Automatic Gain Control) value.
Commands
read minimum:
Command [0]
\x26
Command [1]
\xa2
read maximum:
Command[0]
\x27
Command[1]
\xa2
138
R5976884 RLM SERIES 04/04/2006
See also other documents in the category Barco Projectors:
- R9000908 (55 pages)
- R5976907/00 (51 pages)
- NW-12 (35 pages)
- FLM LAMP HOUSE R5976922/03 (7 pages)
- R9010000 (135 pages)
- R9001769 (57 pages)
- R9010310 (135 pages)
- 1280 (26 pages)
- R59770449/01 (79 pages)
- ICON H250/400 R9010500 (154 pages)
- R9010010 (137 pages)
- CLM HD8 R59770057 (231 pages)
- R5975039 (50 pages)
- CORONIS MFGD 2621 (119 pages)
- DATA 708 (34 pages)
- ULTRA REALITY 7000 (99 pages)
- E-2320 C (SE) (104 pages)
- R9001870 (31 pages)
- SLM R12+ (159 pages)
- R9001390 (59 pages)
- ID LR-6 R9010342 (135 pages)
- R9000977 (60 pages)
- R5976519/00 (105 pages)
- R 9849999 (18 pages)
- R9002327 (55 pages)
- R9001960 (127 pages)
- R9002249 (59 pages)
- iQ Pro G500 (195 pages)
- R9010520 (106 pages)
- R9002328 (153 pages)
- R9001490 (93 pages)
- R5976924 (245 pages)
- R9002790 (83 pages)
- R9003110 (134 pages)
- R500 (195 pages)
- GRAPHICS 500 R9002930 (143 pages)
- RLM G5I PERFORMER R9010320 (150 pages)
- MGP D5 (54 pages)
- R9001190 (48 pages)
- R9001070 (121 pages)
- CORONIS FUSION 4MP/6MP (72 pages)
- R9002038 (45 pages)
- D-ILA LX-5 (52 pages)
- R9002120 (57 pages)
- RLM R6+ PERFORMER R9010270 (165 pages)