4. Web Management





AirLive POE-FSH2422G-250 User’s Manual

15

The POE-FSH2422G-250 PoE Switch can be configured by web based interface, including

administrator, port management, VLAN setting, per port counter, trunk setting, QoS setting,

security filter, configuration/ backup/recovery, miscellaneous, log out, and so on. The

device based smart switch supports main stream browsers, such as IE 6.0~7.0, Firefox

2.0~3.0, to configure the device function. All functions are illustrated below.

4.1 Setup your computer for Web management

The Concept of Subnet

Under the TCP/IP environment, network devices must be on the same subnet in order to

see each other. This means before you can configure the switch through web browser,

your must set your computer to the same subnet as the switch. For two network devices

to be on the same subnet, they must have the following 2 criteria

:

„ Their IP address must be on the same subnet. For example, if one IP address is

192.168.2.1. The other’s IP address must be 192.168.2.x (x is any number between 2

and 254) for Class C subnet. To find out the IP address information for your computer.

Under WinNT/2000/XP, please open Command Line window and type “ipconfig”.

Under Win9x, please run “winipcfg”.

„ They must have the same subnet mask. For example, if one machine is

255.255.255.0. The other machine must also set to the same 255.255.255.0 mask.

Configure your computer’s IP

Before accessing the switch through web browse, please follow the instruction below to

configure your computer’s IP to the same subnet as the switch. If your switch’s IP has not

been changed, it should have the following factory default value: