ANALOG INPUTS

32

33

Analog Inputs.

EVO4 has five 12 bits analog inputs, recorded
up to 1000 times per second each.
You can connect 0-5 Volt signals, ratiometric
potentiometers, pressure sensors, thermo-re-
sistances and K-type thermocouples.

Please, follow the steps:

Connect the sensor to the desired input

Enable the channel in the Channels table

Select the proper sensor type; sensors of
many different types are properly handled,
such a: Temperature sensors, Pressure Sen-
sors, Potentiometers, Generic Sensors.

Set the sampling frequency

Set the unit of measure.

EVO 4

n Temperature sensors

n Pressure Sensors

n Potentiometers

n Generic Sensors

K thermocouples
Thermo-PT100 resistors
Temperature sensors VDO

VDO 40-120 ° C
VDO 50-150 ° C
VDO 60-200 ° C
MSI 0-2 bar
MSI 0-5 bar
MSI 0-10 bar
MSI 0-2000 psi

Distance
Zero-based
Zero Central

0-50 mV
0-500
0-5 V

1

2

3

4

5