beautypg.com

Normal engine operation, Stopping the engine – JLG G9-43A (9151-4003) Operator Manual User Manual

Page 29

background image

Form No. 20127 • G9-43A Owner/Operator Manual

Normal Engine Operation

Observe gauges frequently to be sure all engine systems are functioning

properly.

The voltmeter shows the “charge/discharge” state of the battery charging

system. With the engine running, meter should indicate 13.5 to 14 volts. With

engine stopped, meter indicates battery charge (12 volts).

Be alert for unusual noises or vibration. When an unusual condition is

noticed, park machine in safe position and perform standard shut-down

procedure. (See Page 1.1) Report condition to your supervisor or maintenance

personnel.

Avoid prolonged idling. Idling causes engine temperature to drop and this

permits formation of heavy carbon deposits and dilution of lubricating oil by

incompletely-burned fuel. If the engine is not being used, turn it off.

Stopping the Engine

To stop engine, perform standard shut-down procedure.

• Operate engine at low idle for 3 to 5 minutes before turning it off. This

allows engine coolant and lubricating oil to carry excessive heat away from

critical engine areas, including turbocharger.

Do not “gun” engine before shut down: This practice causes incompletely-

burned fuel to remove oil film from cylinder walls and dilute lubricant in

crankcase.

6.1