JLG 660SJ ANSI Service Manual User Manual
Page 135

SECTION 3 - CHASSIS & TURNTABLE
3120718
– JLG Lift –
3-81
DTC 362 - Megajector voltage supply low.
a. Voltage - Check battery voltage. If the voltage at
the battery is less than 9.5 volts:
The battery is faulty
or
The charging system is faulty
or
The Megajector is faulty.
DTC 363 - Megajector Internal Actuator Fault Detection.
a. Connections - Check power, ground, and CAN
circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.
b. Megajector - Megajector has an internal failure.
Contact JLG Industries for further assistance.
DTC 364 - Megajector Internal Circuitry Fault Detection.
a. Connections - Check power, ground, and CAN
circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.
b. Megajector - Megajector has an internal failure.
Contact JLG Industries for further assistance.
DTC 365 - Megajector Internal Comm Fault Detection.
a. Connections - Check power, ground, and CAN
circuits at the Megajector in addition to all elec-
trical connections. Repair as necessary and
retest.
Megajector - Megajector has an internal failure. Contact
JLG Industries for further assistance.