Chapter 11 – Troubleshooting

TB80/TB85J – 0112622EE

59

Symptom

Constant tone alarm sounds

while the engine is running.

Constant tone alarm sounds and

engine shuts off.

Horn is sounding intermittently

and the overload light is flashing.

Horn is sounding constantly and

the overload light is on.

Platform overload sense system

does not work while operating

the upper controls.

Boom functions do not immedi-

ately return when switching

from drive to boom. There is a

delay in boom functions after

switching the drive/boom switch

to the boom position after driv-

ing the machine with the boom

below horizontal.

All functions stop working.

Possible Cause

No alternator current/broken fan belt.

High engine temperature.

Low oil pressure.

The load in the platform is greater

than the rated capacity.

The platform overload system has

an error.

Drive/boom selector switch is in the

drive position and the main boom is

below horizontal.

System needs calibration.

Platform overload system delay.

Low fluid level in reservoir.

Engine or pump failure.

Circuit breaker is tripped.

Electrical system malfunction.

Platform overload sensor is tripped.

Corrective Action

Turn the engine off. Do not restart the

engine until the cause of no alterna-

tor current has been corrected or the

fan belt is replaced.

Let the engine cool. Do not restart the

engine until the cause of overheating

has been corrected.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be restarted

with low oil pressure, but it will only

run a few seconds before it shuts off

again.

Remove load from the platform until

the alarms stop.

Remove load until at or below rated

capacity. Cycle machine power off,

then on. If alarm continues, system

may need recalibration.

Normal operation. The platform over-

load system is inactive while driving

with the boom below horizontal to pre-

vent accidental activation due to rough

terrain.

Refer the problem to a qualified ser-

vice technician.

Normal operation. The system in-

cludes a 5 second delay to eliminate

rapid stop and restart of movements

if the overload system trips during

operation.

Check fluid level. Add correct type of

fluid if necessary.

Manually stow the machine using the

emergency power system or the

emergency lowering knob.

Push circuit breaker button in to reset.

Manually lower the boom using the

emergency lowering knob.

If horn is sounding and red overload

light is on or blinking, remove weight

from the platform until the load is at

or below rated capacity.

This manual is related to the following products: