Chapter 7 – Prestart Inspection

TB80/TB85J – 0112622EE

29

Figure 7.6 – Emergency Power Battery

Battery Fluid Level

Remove the caps from each battery. Visually check the

battery fluid level. If the level is not within 6 mm (

1

/

4

″) of

the bottom of the filler neck inside each hole, add dis-

tilled water.

Replace the caps on the batteries. The caps must be in

place and tight during machine operation.

Battery Terminals

Check the top of the batteries, the terminals, and cable

ends. They should be clean and free of corrosion. Clean

the top of the batteries if necessary. Clean the terminals

and cable ends with a wire brush or terminal cleaning

tool. All cable ends must be securely fastened to the

terminals.

Cables and Wiring Harness

Inspect all cables and wiring for wear and/or physical

damage such as loose connections, broken wires, and

frayed insulation. Check the wiring in areas where a change

in routing direction may cause them to become pinched

(refer to Figure 7.7). Make sure the cables and wires are

properly routed to avoid sharp edges, pinching, and scuff-

ing.

Figure 7.7 – Cables and Wiring Harness

Hydraulic System

Hydraulic power is supplied from an engine driven vari-

able displacement piston pump.

A

Danger

Hydraulic fluid escaping under pressure can have

enough force to inject fluid into the flesh. Serious

infection or reaction can result if medical treatment

is not given immediately. In case of injury by escap-

ing hydraulic fluid, seek medical attention at once.

The hydraulic reservoir is behind the door on the left side

of the turntable. The pump is mounted on the engine.

Fluid Level

Check the hydraulic reservoir fluid level with the aerial

platform stowed on a level surface. The fluid level must

be between the full and add marks as viewed on the sight

glass (refer to Figure 7.8).

Figure 7.8 – Fluid Level Indicator

A

Caution

Not all hydraulic fluid is suitable to use in the hy-

draulic system. Some have poor lubricating char-

acteristics and can increase component wear. Only

use hydraulic fluid as recommended.

If necessary, remove the filler cap and add fluid of the

proper type. Refer to Chapter 2 for the proper type and

grade of hydraulic fluid to use. The need to regularly add

fluid indicates a leak that should be corrected.

The sight glass on the reservoir has an internal thermom-

eter to measure the fluid temperature. The temperature

should be less than 93°C (200°F).

Fluid Filter

Checking the condition of the hydraulic fluid filter is part

of the machine maintenance schedule and should not be

performed by the operator.