Chapter 11 – troubleshooting – Snorkel TB85J CE User Manual
Page 61

TB80/TB85J – 0112622EE
57
Chapter 11 – Troubleshooting
The troubleshooting chart may be used to locate and
eliminate situations where machine operation may be
interrupted. If the problem cannot be corrected with the
action listed, stow the machine and remove it from ser-
vice. Repairs must be made by qualified maintenance
personnel.
Troubleshooting Chart
Symptom
Engine will not start from lower
or upper controls.
Engine will not start from
lower controls.
Possible Cause
Out of fuel. The engine will crank,
but will not start.
Engine is cold.
High engine temperature.
Low oil pressure.
Switches are set wrong. The engine
will not crank.
The control selector switch was left
in the lower control position for 30
seconds or longer before starting the
engine.
The main system circuit breaker on
the wiring box has tripped. The en-
gine will not crank.
Corrective Action
Add correct type of fuel. Try start-
ing the engine for 20 seconds and
then let the starter motor cool for
60 seconds. Repeat as necessary.
Cummins engine – plug the block
heater in eight hours before starting
the engine.
Deutz engine – hold the manifold
heater switch on for about a minute
before starting the engine. Hold the
switch on until the engine starts.
Let engine cool. Do not restart the
engine until the cause of overheat-
ing has been corrected.
Do not try to start the engine until
the cause of low oil pressure has
been corrected. The engine can be
restarted with low oil pressure, but
it will only run a few seconds before
it shuts off again.
Turn the battery disconnect switch
on and then at the lower controls:
• Turn the control selector switch
off.
• Pull the emergency stop button
outward.
• Place the controls selector in
the lower control position.
• Wait for 5 seconds and then
press the switch to start.
Press the start button within 30 sec-
onds of placing the control selector
in the lower controls position.
Push the main system circuit
breaker button back in. If the button
pops back out, refer the problem to
a qualified service technician.