Chapter 4 – Safety Devices

TB80/TB85J – 0112622EE

17

The horn will sound and the light will stay on until the

excess load is removed from the platform and the start

switch is turned off and back on, resetting the system.

At that time, the boom and drive functions are opera-

tional.

A

Danger

The aerial platform can tip over if it becomes un-

stable. Death or serious injury will result from a tip-

over accident. Do not exceed the capacity values

indicated on the platform rating placard.

The overload sensing system is not active when the ma-

chine is being driven with the main boom below horizon-

tal and fully retracted. This allows the machine to be driven

without the system sensing an overload due to rough

ground conditions.

To eliminate repeated tripping of the system during ma-

chine operation, there is a five second delay in machine

functions following:

• starting the engine.

• placing the drive/boom selector switch in the boom

position when the main boom is below horizontal and

fully retracted.

• removing excess load from the platform.

Engine Protection Systems

A constant tone alarm will sound to warn against high

engine temperature or low oil pressure.

The engine will shut-down if the operating temperature

exceeds a preset level or if the oil pressure is too low for

safe operation. An engine temperature gauge is on the

top of the lower control panel (refer to Figure 4.7).

High Engine Temperature Alarm

If the coolant in a Cummins engine exceeds the engine

operating temperature an alarm will sound and the en-

gine will shut off.

If the oil in a Deutz engine exceeds 110°C (230°F) an

alarm will sound and the engine will shut off. Any time

there is no alternator current being produced, an alarm

will sound and the engine will shut off. This prevents high

engine temperature if the fan belt breaks.

Do not restart the engine until the condition that caused

the overheating has been corrected.

Low Oil Pressure Alarm

The low oil pressure alarm sounds when the engine oil

pressure is near the lower limit for safe engine operation.

If the alarm sounds, lower the platform to the ground and

then turn the engine off. Do not restart the engine until

the condition that caused the low oil pressure has been

corrected.

Platform Overload Sensing System

Boom and drive functions are stopped when the platform

load reaches or exceeds rated capacity. The horn will

sound intermittently and the red light (refer to Figure 4.6)

will illuminate when the platform rated work load is ex-

ceeded.

Figure 4.6 – Upper Controls

The horn will sound and the light will flash until the ex-

cess load is removed from the platform. At that time, the

boom and drive functions are again operational.

If the overload exceeds rated platform capacity by more

than 20 percent, the system will error out, stopping all

boom and drive functions. The horn will then sound con-

tinuously and the red light will stay illuminated at the

upper and lower controls (refer to Figure 4.7).

Figure 4.7 – Lower Control Panel

Platform

Overload Light

Engine

Temperature

Gauge

Platform