beautypg.com

Operation from ground control box 9-2, Operation from ground control box, 9-2, Operation from ground control box -2 – Snorkel MHP34J(Bi-Energy Option) User Manual

Page 52: Emergency operation

background image

Operation From Ground Control Box

Figure 9.5 - Manual Lower Valve

1. Open manual valve



to lower platform

NOTE

To operate the slew function from the ground
control box when using the emergency lowering
valve the Master Key Switch, and Emergency
Stop
switch must be on and the
Platform/Ground Selector must be set to
ground. The slew direction can then be selected
using the slew switch

†

(see Figure 9.1). The

slew function will only operate while the booms
are lowering.

page 9 - 2

MHP12/34J – 11447A

9. Emergency Operation

This manual is related to the following products: