Emergency operation, Emergency operation procedures 9-1, Operation from platform control box 9-1 – Snorkel MHP34J(Bi-Energy Option) User Manual
Page 51: Emergency operation, 9-1, Operation from platform control box, 9-1, Procedures, 9-1, Emergency operation procedures -1, Operation from platform control box -1

9. Emergency Operation
■
Emergency Operation Procedures
The following procedures are emergency proce-
dures only. DO NOT use them for normal operation.
Their purpose is to get the platform and operator
safely to ground when the MHP12/34J will not start
or some other problem keeps the platform from low-
ering in the normal way.
❑
Operation From Platform Control Box
Switch settings listed in the three steps below must
exist at the ground before emergency operation
procedures will work at the platform control box:
Figure 9.1
1. The Master Key Switch
must be ON (see
Figure 9.1).
2. The Emergency Stop switch
must be
(ON) (see Figure 9.1).
3. The Platform/Ground Selector switch
(see Figure 9.1) must be set to PLATFORM.
Figure 9.2
4. Set the Emergency Stop switch
to ON
(see Figure 9.2).
5. Set the Anti-Restart switch
(see Figure
9.2) to ON.
Figure 9.3
6. Step on the platform foot switch
(see
Figure 9.3).
Figure 9.4
7. Hold the Emergency Lower switch
(see
Figure 9.4) down and the platform will begin
lowering.
NOTE
To slew when using emergency lowering operate
the slew switch
in the direction required (see
Figure 9.4).
MHP12/34J – 11447A
page 9 - 1