Chapter 11 – Troubleshooting

AB60J – 0181972

63

Symptom

Possible Cause

Corrective Action

Constant tone alarm sounds and

engine shuts off.

High engine temperature.

Let the engine cool. Do not restart

the engine until the cause of over-

heating has been corrected.

Low oil pressure.

Do not restart the engine until the

cause of low oil pressure has been

corrected. The engine can be re-

started with low oil pressure, but it

will only run for a few seconds before

it shuts off again.

All functions stop working.

Low fluid level in reservoir.

Check fluid level. Add correct type of

fluid if necessary.

Engine or pump failure.

Manually stow the machine using the

emergency lowering knob.

Circuit breaker is tripped.

Push circuit breaker button in to

reset.

Electrical system malfunction.

Manually lower the boom using the

emergency lowering knob.

Lower controls do not work.

Battery disconnect switch turned off.

Place switch in the on position.

Emergency stop button at lower con-

trols is pushed in to the off position.

Pull the emergency stop button

outward.

Control selector switch is in the upper

control position.

Place the switch in the lower control

position.

Ground operation switch not held in

the on position.

Hold the ground operation switch in

the on position while operating the

control toggle switches.

Upper controls do not work.

Battery disconnect switch turned off.

Place switch in the on position.

Emergency stop button at lower and

upper controls is in the off position.

Pull the emergency stop buttons

outward.

Control selector switch at lower con-

trols is in the lower control position.

Place switch in the upper controls

position.

Platform foot switch not engaged.

Step down on platform foot switch

while operating controls.

Upper and lower controls do not work

– machines with bumpguard system

option only.

The bumpguard has come into

contact with a stationary object and

one or both of the light beams are

broken.

At the upper controls, hold the prox-

imity override switch up. Use the

controls to move the platform away

from the stationary object. Return the

proximity override switch to normal

operation.

Boom and drive functions seem

sluggish.

Hydraulic oil is cold and thick.

Use cold weather hydraulic oil as

recommended for weather condi-

tions. Warm oil before operating the

machine.

Turntable and main boom func-

tions do not work from the upper

controls.

Boom speed knob set too slow.

Turn knob toward fast.

Riser and/or main boom drifts

down.

The emergency lowering valve is

open.

Turn the emergency lowering knob

to close the valve.

Hydraulic system malfunction.

Stow the machine and do not oper-

ate until repairs are made.

Platform will not raise and alarm is

sounding.

Machine not on a level surface.

Lower the platform and drive to a

level surface.