beautypg.com

Emergency stop, Emergency power, Emergency lowering – Snorkel AB60J User Manual

Page 38: Warning, Danger

background image

Chapter 7 – Prestart Inspection

34

AB60J – 0181972

4. Slowly turn the emergency lowering knob to open

the bleed down valve on the riser boom lift cylinder

(refer to Figure 7.11). The riser boom should slowly

lower.

Figure 7.11 – Riser Boom Emergency

Lowering Knob

5. Turn the knob to close the cylinder bleed down

valve.

6. Slowly turn the emergency lowering knob to open

the bleed down valve on the main boom lift cylinder

(refer to Figure 7.12). The main boom should slowly

lower.

Figure 7.12 – Main Boom Emergency

Lowering Knob

7. Turn the knob to close the cylinder bleed down

valve.

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury could result from such accidents. Fully close

the emergency lowering valves before operating the

aerial platform.

Warning

The potential for an accident increases when operat-

ing an aerial platform that is damaged or malfunction-

ing. Death or serious injury could result from such

accidents. Do not operate the aerial platform if it is

damaged or malfunctioning.

6. Test the operation of each function in both direc-

tions.

Note

When checking the turntable rotation function in the clock-

wise direction, the turntable will rotate toward you.

Emergency Stop

To test the emergency stop button from the lower con-

trols:

1. Push the emergency stop button (refer to Figure 7.10)

inward to turn off electrical power.

2. Test the lower control functions to make sure they do

not operate.

Emergency Power

To test the emergency power system from the lower

controls:

1. Place the battery disconnect switch, the emergency

stop switch and the start switch in the on position.

2. Hold the engine/emergency power switch (refer to

Figure 7.10) downward and the ground operation

switch upward to operate the aerial platform from the

lower controls using the emergency power system.

Emergency Lowering

The riser and main booms can be lowered in an emer-

gency using their respective emergency lowering knobs.

The emergency lowering knobs are at the base end of

the lift cylinders.

Use the following procedure to test the emergency lower-

ing system:

1. Use the lower controls to raise the main and riser

booms.

2. Turn the engine off.

Danger

Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components. Make sure all person-

nel stand clear while lowering the platform with the

emergency lowering knob.

3. Make sure there is nothing in the way to obstruct the

platform when it lowers.

Emergency

Lowering Knob

Emergency

Lowering Knob