beautypg.com

Chapter 10 – emergency operation, Emergency power system, Lower controls – Snorkel AB60J User Manual

Page 61: Upper controls, Emergency lowering, Caution

background image

AB60J – 0181972

57

Figure 10.2 – Lower Controls

3. Pull the emergency stop button outward.

4. Place the control selector switch in the lower controls

position.

5. Hold the ground operation switch upward to the on

position while holding the engine/emergency power

switch downward to the emergency power position.

6. Hold the appropriate function toggle switch in the

desired direction.

Upper Controls

For the upper controls to be operational:

The battery disconnect switch must be in the on

position.

The emergency stop button at the lower controls must

be in the on position.

The start switch at the lower controls must be in the

on position.

The control selector switch at the lower controls must

be in the upper control position.

Use the following procedure to operate the machine using

the emergency power system from the upper controls.

1. Pull the emergency stop button outward (refer to

Figure 10.3).

If the main hydraulic system fails, the aerial platform

may be lowered and stowed using the emergency power

system. The main boom and riser boom may be lowered

using the emergency lowering knobs. The machine may

be towed at slow speeds using the optional tow kit if the

drive system fails.

Refer to Emergency Power System, Emergency Lower-

ing, or Towing for the appropriate procedure.

Emergency Power System

The emergency power system can be used to operate

the machine from the lower or upper controls.

Caution

The emergency power system is for emergency low-

ering and stowing only. The length of time the pump

can be operated depends on the capacity of the bat-

tery. Do not use this system for normal operation.

Only use the emergency power system if the main power

system fails.

Lower Controls

Use the following procedure to operate the machine using

the emergency power system from the lower controls.

1. Place the battery disconnect switch in the on position

(refer to Figure 10.1).

Figure 10.1 – Battery Disconnect Switch

2. Place the key in the start switch (refer to Figure 10.2)

and turn the switch to the on position.

Chapter 10 – Emergency Operation

Emergency

Stop Button

Control Selector

Switch

Ground Operation

Switch

Start Switch

Engine/Emergency

Power Switch

Battery

Disconnect Switch