Chapter 7 – Prestart Inspection

38

AB60J – 0181972

Emergency Stop

To test the emergency stop button from the upper con-

trols:

1. At the lower controls, start the engine and place the

control selector switch in the upper control position.

2. At the upper controls, push the emergency stop but-

ton (refer to Figure 7.19) inward to turn off electrical

power.

3. Verify that the engine shuts off and the upper control

functions do not operate.

Emergency Power

To test the emergency power system from the upper

controls:

1. Turn the battery disconnect switch on.

2. At the lower controls, pull the emergency stop button

outward and place the start switch in the on position.

Place the control selector switch in the upper control

position.

3. At the upper controls (refer to Figure 7.19), pull the

emergency stop button outward and place the start

switch in the on position.

4. Hold the engine/emergency power switch in the

emergency power position and step on the platform

foot switch to verify operation of the aerial platform

using the emergency power system.

Horn

The machine may be equipped with an optional horn.

Operate the horn to ensure that it sounds to warn

personnel in the area.

Electrical Power Outlet

Connect a source of 110 Volt AC power to the power-input

connector located inside the rear of the turntable (refer

to Figure 7.20).

Figure 7.20 – Power-Input Connector

Some machines may have an electrical outlet at the

platform, but no power-input connector on the chassis. In

that case, power is supplied by an optional AC generator.

An external power source is not required.

With the engine running, place the machine/generator

control (refer to Figure 7.21) in the generator position to

provide electrical power to the outlet at the platform and

to the outlet on the end of the generator housing.

Figure 7.21 – Upper Controls

Plug an electrical tool into the receptacle at the platform

and at the generator and try to operate the tool to verify

proper operation of the outlet.

The outlet at the platform is equipped with a ground fault

circuit interrupter (GFCI). Use the following procedure to

test the GFCI.

1. Push the test button (refer to Figure 7.22).

Figure 7.22 – Electrical Power Outlet

2. Plug an electrical tool into the outlet and verify the

power is off.

If the power was off, push the reset button to

restore power.

Reset Button

Test Button

Reset Button

Test Button

Power-Input

Connector

Machine/Generator