Chapter 11 – Troubleshooting

62

AB60J – 0181972

Symptom

Possible Cause

Corrective Action

Engine will not start from lower

controls.

The main system circuit breaker on

the lower control panel has tripped.

The engine will not crank.

Push the main system circuit breaker

button back in. If the button pops

back out, refer the problem to a quali-

fied service technician.

Engine will not start from upper

controls.

Switches are set wrong. The engine

will not crank.

Turn the battery disconnect switch on

and then at the lower controls:

Turn the start switch off.

Pull the emergency stop button

outward.

Place the control selector switch

in the upper control position.

Place the start switch in the on

position.

From the upper controls:

Turn the start switch off.

Pull the emergency stop button

outward.

Place the start switch in the on

position for 5 seconds and the

then turn the switch to start.

Platform foot switch is activated.

Do not step on foot switch while start-

ing the engine.

The start switch was left in the on

position for 30 seconds or longer

before turning it to start.

Turn the start switch back to off, then

to start within 30 seconds.

The circuit breaker on the upper

control panel has tripped. The engine

will not crank.

Push the circuit breaker button back

in. If the button pops back out, refer

the problem to a qualified service

technician.

Engine starts from the upper con-

trols but no boom functions work

– machines with AC generator op-

tion only.

The AC generator switch is in the

generator position.

Place the switch in the machine posi-

tion to operate machine functions.

Engine dies when the control selector

switch at the lower controls is placed

in the upper control position.

Upper controls are not set-up prop-

erly.

At the upper controls, pull the emer-

gency stop button upward and turn

the start switch on.

Constant tone alarm sounds while

the engine is running.

High engine temperature.

Lower the platform and turn the en-

gine off to let it cool. Do not restart the

engine until the cause of overheating

has been corrected.

Low oil pressure.

Lower the platform and turn the

engine off. Do not restart the engine

until the cause of low oil pressure has

been corrected.

No alternator current/broken fan

belt.

Turn the engine off. Do not restart the

engine until the cause of no alterna-

tor current has been corrected or the

fan belt has been replaced.