Introduction

This manual covers all models of the LX Series

Work Platforms. This manual must be stored on

the machine at all times.

Pre-Operation and Safety

Inspection

Carefully read, understand and follow all safety

rules, labels, and operating instructions, then

perform the following steps each day before

use.

1. Open modules and inspect for damage, oil

leaks or missing parts.

2. Check the hydraulic oil level sight gauge on

the hydraulic tank with the platform fully

lowered. Add ISO #46 hydraulic oil if neces-

sary.

3. Check that fluid level in the battery is correct

(See Battery Maintenance, Page 7).

4. Check the engine oil level and fuel level.
5. Check that all guardrails are in place, the slide

out deck extension is secured with the pin and

all fasteners are properly tightened.

6. Check tire pressure; 50 psi (3.4 bar).
7. Carefully inspect the entire work platform for

damage such as cracked welds or structural

members, loose or missing parts, oil leaks,

damaged cables or hoses, loose connections

and tire damage.

8. Move machine, if necessary, to unobstructed

area to allow for full elevation.

9. Place chassis and platform emergency stop

switches in the ON position (Figure 1 & 2) by

pulling the buttons out.

10.Verify platform/chassis switch is on PLAT-

FORM (Figure 1).

11.Dual Fuel Models: set dual fuel selector to

desired position. Set to the center position to

purge the system when switching fuels. If the

machine is to be operated on propane, open

the supply valve on the tank.

Note: When using LP gas, use clean, water free

liquid petroleum gas, preferably from a bulk

storage tank. Follow the instructions located on

the power module tray for filling the tank.

If you smell propane, close the supply

valve on the tank immediately until you

have located and corrected the leak.

12.While the engine is cool check the engine

coolant level.

DO NOT check coolant when engine or

radiator is hot, hot coolant can cause

severe burns.

System Function Inspection

STAND CLEAR of the work platform

while performing the following checks.
Before operating the work platform survey

the work area for surface hazards such as

holes, drop-offs, bumps and debris.
Check in ALL directions, including above

the work platform, for obstructions and

electrical conductors.
Protect control console cable from possible

damage while performing checks.

Figure 1: Chassis, Left Side

Stop

Button

Platform/Chassis

Switch

Emergency Stop Switch

Fuel Selector Switch

Lower Button

Raise Button

Start

Button

Throttle

Button

Tilt Sensor

Choke/Glow

Plug Button