Lukas SP 512 User Manual
Page 39

39
*
1 MPa = 10 bar
**
Necessary volume of hydraulic fl uid in the hydraulic unit to operate the unit
(differential volume on piston / rod side)
type
SP 310
ref. no.
81-10-25
(111010000/171010000)
min. spreading force
(25mm / 0.98in. from the tips)
[kN]
46
[lbf.]
10300
max. spreading force
[kN]
308
[lbf.]
69200
spreading force HSF
(according to NFPA)
[kN]
55
[lbf.]
12400
spreading force LSF
(according to NFPA)
[kN]
44
[lbf.]
9890
max. spreading distance
[mm]
720
[in.]
28.3
max. pulling force (on mounting
borehole for chain set)
[kN]
41
[lbf.]
9200
pulling distance (on mounting
borehole for chain set)
[mm]
573
[in.]
22.6
pulling force HPF
(according to NFPA)
[kN]
32
[lbf.]
7200
pulling force LPF
(according to NFPA)
[kN]
25
[lbf.]
5600
dimensions
l x w x h
[mm]
783 x 345 x 192
[in.]
30.8 x 13.6 x 7.6
weight incl. hydraulic fl uid
[kg]
19,9
[lbs.]
43.9
max. operating pressure
[Mpa] *
70
[psi.]
10000
min. needed volume
of hydraulic fl uid
[l] **
0,24
[gal.-US]
0.07
coupling system
mono-coupling
classifi cation acc. to DIN EN 13204
AS46/720-20