Trouble
Control
Cause
Solution
Especially by usage
of mono-couplings:
Leak on the handhold
check the
connections of the
hoses
hose connection
to the couplings
interchanged
reconnect the hoses
to the coupling in the
right way
Returnline
disabled
disconnect the
returnline from the
coupling, clean it and
reconnect it.
with mono-coupling-
system: Leak in the
couplings
Is the coupling
damaged?
coupling damaged Coupling must be
replaced immediately
with quick-
disconnect-coupling-
system: Leak in the
couplings
Is the coupling
damaged?
coupling damaged Coupling must be
replaced immediately
Is the leak only on
the coupling male?
Safety valve
reacted
After pressure
release there is no
more leakage.
12. Technical data
Since all values are subject to tolerances, minor differences may occur between the data on
your equipment and the data in the following schedules!
NOTE:
The following tables contain only the technical data required for standard
acceptance.