7. Wiring
7.1. Power and Ground
It is imperative that a system utilizing Master and Remote tank level displays connected by the 1-wire data line have a
common ground. The remote displays will not follow the master display otherwise.
Pin 1
System voltage
Pin 2
Ground
7.2. Dim Function
The LEDs on the tank level display can be dimmed to a user selectable dim setting by applying system voltage to the
Dim display Input.
Pin 3
Dim display input (system voltage)
7.3. Transducer Connection
Pin 6
Sensor power (+5)
Pin 7
Sensor signal
Pin 8
Sensor ground
7.4. Communication Data Line(s)
Pin 4
CAN high communication line (or 1-wire communication line)
Pin 5
CAN low communication line