Connections, Onnections, Terminal function and polarity – Class1 Total System Manager User Manual
Page 8
8
TERMINAL
FUNCTION
POLARITY
1
Load Manager Enable
Ground
2
Output Load # 2
Pos/Gnd
3
Output Load # 4
Pos/Gnd
4
Output Load # 6
Pos/Gnd
5
Output Load # 8
Pos/Gnd
6
Output Load #10
Pos/Gnd
7
Output Load #12
Pos/Gnd
8
Auxiliary Battery Alarm
Positive
9
Low Voltage Alarm
Ground
10
Master Switch
Either
11
No Connection
----------
12
Main Battery Voltage
Positive
C
ONNECTIONS
Mating Connector
AMP 770587-1
Socket (Loose Form)
AMP 171639-1
16-18 Ga
Socket (Strip Form)
AMP 171637-1
16-18 Ga
Crimping Tool
AMP 90760-1
Pro-Crimper
Contact Extraction Tool
AMP 189727-1
Connector and Socket Kit
P.N. 101536
Mating Pigtail
P.N. 101538
TERMINAL
FUNCTION
POLARITY
13 Output Load # 1
Pos/Gnd
14 Output Load # 3
Pos/Gnd
15 Output Load # 5
Pos/Gnd
16 Output Load # 7
Pos/Gnd
17 Output Load # 9
Pos/Gnd
18 Output Load # 11
Pos/Gnd
19 Output Variable Trip
Positive
20 Output Fast Idle
Positive
21 Parking Brake
Either
22 No Connection
-----------
23 Input Aux. Battery
Positive
24 Ground
Ground
Terminal Function and Polarity
T
HE
BATTERY
PLUS
(
TERM
. #12)
AND
GROUND
(
TERM
. #24 )
SHOULD
BE
WIRED
AS
DIRECT
TO
THE
BATTERY
AS
POSSIBLE
.
These are the connections that the Total System Manager uses to derive it’s voltage information.
1
2
3
4
5
6
7
8
9
10
11
12
24 23 22 21 20 19 18 17 16 15 14 13
Mating Connector viewed from wire insertion end
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Load 1
Load 3
Load 5
Load 7
Load 9
Load 11
Var Trip
Fast Idle
Park Brake
NC
Aux Batt IN
Ground
LM enable
Load 2
Load 4
Load 6
Load 8
Load 10
Load 12
Aux Batt Alarm
Alarm
Master SW
NC
Batt +
J
UMPERS
J1
AND
J2
MUST
BE
SET
TO
MATCH
THE
POLARITY
OF
THE
P
ARKING
B
RAKE
AND
M
ASTER
S
WITCH
I
NPUTS
.
The polarity of Loads 1-12 are unit dependent.