Programming, Rogramming – Class1 Total System Manager User Manual

Page 6

background image

6

P

ROGRAMMING

Programming of the

Total System Manager is accomplished using push-

button switches and a straightforward menu approach. A digital display and 4 LED’s
provide feedback to the programmer.

PROGRAM

SWITCH

This switch and the USER switch when held
until the display shows three (3) dashes (---)
puts the T.S.M. into the programming mode.
When held until (dEF) is displayed (aprox.
15 seconds), the factory defaults are pro-
grammed into the system.
The final programming step is to hold the
PROGRAM switch until (Pro) is displayed
to save the new values.

PROGRAM MENU SWITCHES

NEXT

SWITCH

Pressing this switch will cycle through each
output, the LED next to each output will light
when that output is selected and the digital
display will also indicate the load selected
(L01-L13).

MODE SWITCH

AND

LED’

S

The MODE switch toggles through the avail-
able modes for load management.

RESPONSE

LED

Output is ON only when the
parking brake

IS

NOT

set.

SCENE

LED

Output is ON only when the
parking brake

IS

set.

BOTH

LED

S

The output can be ON re
gardless of the parking brake
status.

ACTIVE SWITCH

AND

LED’

S

This toggles the switch source for the se-
lected output.

IGNITION

LED

Output is tied to the ignition

switch.

WRN

MASTER

Output is tied to the master

switch.

PRIORITY

SWITCH

This switch selects the sequence and shed
priority level for the selected output. A small
digital display shows the priorities (P00-P08)
as they cycle through. Loads sequence on
in 1-8 priority and shed off in 8-1 priority. Pri-
ority 0 loads never shed, but will sequence
on and off.

USER

This adjusts the setpoint voltage for output
#13 (term. 19).
Pressing this button increases the ‘trip’ point
in 0.1 volt increments from 10.5 VDC to 15.0
VDC.

NOTE

: If the setpoint is 13.8 volts or higher,

output #13 will activate when the system volt-
age rises to the setpoint. If the setpoint is
less than 13.8 volts, output #13 will activate
when the voltage falls to the setpoint.

STORE

SWITCH

The STORE switch saves the current con-
figuration for the selected output. The dis-
play will indicate that the values were saved
by showing three (3) dashes (---) and then
the load number (Lxx).

RESPONSE

SCENE

NEXT

STORE

MODE

PRIORITY

USER

DATA

PROGRAM

IGNITION

WRN MASTER

ACTIVE