beautypg.com

Display panel, The indicator panel consists of four led’s – Class1 ESM3 User Manual

Page 3

background image

3

Display Panel

STANDARD PANEL DISPLAY

The

Class1 Electrical System Manager is supplied with an indicator panel.

The indicator panel is designed to fit in a standard rocker switch cutout ( 7/8” x 1-1/2”).

The indicator panel consists of four LED’s:

P

OWER

ON (

GREEN

WIRE

) T13

This LED illuminates when power is applied to the System Manager.

B

ATTERY

W

ARNING

(

YELLOW

WIRE

) T8

This LED activates when the system voltage drops below 11.9 VDC.

I

SOLATED

B

ATTERY

L

OW

(

BLUE

WIRE

)

OPTION

T7

This LED illuminates when an auxiliary battery voltage drops below 11.9
VDC.

O

VER

-V

OLTAGE

OR

F

AST

I

DLE

(

BROWN

WIRE

) T15

This LED illuminates when system voltage drops below 12.8 VDC or rises
above 15.0 VDC as configured by SW1 switch 3.

G

ROUND

(

BLACK

WIRE

)

Connected to system ground.