Pin
Hardware Reference
7100-XXXX-62
7101-XXXX-63
Function
Hardware Specification
Notes
C1-10
+12V_R8C_CPU
Battery Perm Power
Dedicated power management
CPU
Full time battery power. MUST be
powered bef ore the ignition switch input
is triggered. (See C1-65.)
C1-11
Coil 4
Coil 4
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-12
Coil 3
Coil 3
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-13
Coil 2
Coil 2
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-14
Coil 1
Coil 1
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-15
Coil 6
Coil 6
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-16
Coil 5
Coil 5
25 mA max source current
0–5V Falling edge f ire. DO NOT connect
directly to coil primary . Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
C1-17
LowsideSwitch_2
Coolant Fan 1 Control
Lowside switch, 4A max, NO
internal f ly back diode.
See "LowSide Assignment Tables" f or
output assignment.
C1-18
LowsideSwitch_3
MIL Output
Lowside switch, 4A max with
internal f ly back diode. Inductiv e
load should NOT hav e f ull time
power.
See Wizard page "LowSide Assignment
Tables" f or output assignment.
MIL Activ ates when any of the f ollowing
f lags are true: ErrorAirTemp, ErrorBaro,
ErrorCoolantTemp, ErrorEBP,
ErrorFuelPressure, UEGO_0_Diag_error,
UEGO_1_Diag_error, ErrorMAFAnalog,
ErrorMAFDigital, ErrorMAP,
ErrorOilPressure, ErrorThrottle.
C1-19
AGND_1
Sensor Ground
Dedicated analog ground
Analog 0–5V sensor ground
C1-20
AGND_1
Sensor Ground
Dedicated analog ground
Analog 0–5V sensor ground
C1-21
Crankshaf t Position
Sensor Hall
Crankshaf t Position
Sensor Hall
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Cam/Crank f or
options.
C1-22
Camshaf t Position
Sensor 1 Hall
Camshaf t Position
Sensor 1 Hall
10K pullup to 12V. Will work with
ground or f loating switches.
See Setup Wizard page Cam/Crank f or
options.