Pin #
OBD2A Honda/Acura
AEM EMS 30-6060
I/O
Availability
B1
---
Idle 5
Output
Avail, Switched +12V/GND, 1.5A max
B2
---
Idle 6
Output
Avail, Switched GND/+12V, 1.5A max
B3
---
High Side Driver 4
Output
Available, Switched +12V, 1.5A max
B4
---
Idle 2
Output Avail, Switched GND/+12V, 1.5A max
B5
---
---
---
---
B6
---
Injector 10
Output
Available, Injector GND, 1.5A Max
B7
---
Coil 2
Output
Avail, Rising Edge Trigger Coil Out
B8
---
ADCR 13
Input
Avail, 0-5 Volt Input, 100k Pull Up
B9
---
Coil 3
Output
Avail, Rising Edge Trigger Coil Out
B10
---
Coil 4
Output
Avail, Rising Edge Trigger Coil Out
B11
---
Idle 4
Output
Avail, Switched GND/+12V, 1.5A max
B12
---
Idle 8
Output
Avail, Switched GND/+12V, 1.5A max
B13
---
---
---
---
B14
---
Sensor GND
Output
Dedicated, sensors only
B15
---
Switch 2
Input
Available, Switched Input
B16
---
Injector 7
Output
Available, Injector GND, 1.5A Max
B17
---
+5V Sensor power
Output Dedicated +5v Out for Sensor Reference
B18
---
---
---
---
B19
---
---
---
---
B20
---
Low Side Driver 9
Output
Avail, Switched Ground, 1.5A Max
B21
---
Injector 6
Output
Available, Injector GND, 1.5A Max
B22
---
Sensor GND
Output
Dedicated, sensors only
B23
---
Switch 3
Input
Available, Switched Input
B24
---
Injector 8
Output
Available, Injector GND, 1.5A Max
B25
---
EGT 1
Input
Available, jumper set for 0-5V Input