D. chain lubrication, 1000 hour intervals), General maintenance – SkyTrak 10042 Operation Manual User Manual
Page 172

170
Model 10042
Rev. 11/03
General Maintenance
D. Chain Lubrication
(1000 Hour Intervals)
After inspection and before 
being returned to service, 
chains must be lubricated 
with a quality chain lubricant (“LUBRIPLATE” Chain & Cable Fluid, “LPS3” 
or equivalent).
The lubricant must penetrate the chain joint to prevent wear. Applying 
lubricant to the external surfaces will prevent rust, but the chains should be 
articulated to make sure the lubricant penetrates to the working surfaces 
between the pins and links.
To prepare the chain for lubrication, the chain plates should be brushed with 
a stiff brush or wire brush to clear the space between the plates so that 
lubricant can penetrate to the working surfaces.
Lubricant may be applied with a narrow paint brush or directly poured on, 
but the chain should be well flooded with lubricant and the boom should be 
extended and retracted to be sure that the lubricant penetrates to the 
working surfaces. All surplus lubricant should be wiped away from the 
external surfaces. DO NOT use a solvent for this wiping operation.
Regular application of lubricant is necessary to make sure that all working 
surfaces are adequately lubricated. In extremely dusty conditions, it may be 
necessary to lubricate the chains more often.
Lubrication of chains on vehicles working consistently in extreme hot or cold 
conditions requires special consideration. It is important that a reputable 
lubrication specialist, a Sky Trak Distributor or the vehicle distributor be 
consulted for guidance.
1000
OH2690